Fire doors are a fundamental passive fire protection element, providing compartmentation between areas of a building. They must meet strict performance requirements under AS1905 and the BCA to function correctly in a fire event.
What Makes a Fire Door Compliant?
A compliant fire door is not simply a heavy door, it is a tested and certified system comprising the door leaf, frame, hardware, seals and glazing if applicable. Each component must be tested as part of the complete door assembly to the requirements of AS1905. Fire doors are rated by their Fire Resistance Level (FRL), typically expressed in terms of integrity and insulation performance. Common ratings for residential and commercial buildings include -/60/30 and -/120/60. Compliance also requires correct installation, including appropriate clearances, hardware selection and door closer operation.
Annual Inspection Requirements
Fire doors require regular inspection and maintenance to remain compliant. Under the BCA and most state fire safety regulations, fire doors must be inspected and certified annually as part of the building's Annual Fire Safety Statement. Inspections typically cover door operation, hardware function, seal condition, frame integrity, signage requirements and overall fire door system performance. Any deficiencies identified must be rectified before the AFSS can be submitted.
Common Fire Door Deficiencies
The most common fire door deficiencies found in Australian buildings include incorrect clearances between door leaf and frame or floor, damaged or missing intumescent seals, non-compliant or missing door hardware, non-closing or non-latching door closers, unauthorised modifications such as pet doors or vision panels, and non-certified replacement components. Many of these deficiencies arise from minor maintenance and modification activities carried out over the life of the building without proper compliance consideration.
Rectification and Upgrade Options
When fire door deficiencies are identified, the rectification approach depends on the nature and severity of the deficiency. Minor hardware and seal deficiencies can often be addressed through targeted repairs. More significant deficiencies, particularly those involving the door leaf, frame or glazing, may require full door replacement. One Stop Fire assesses each deficiency on its merits and provides the most cost-effective compliant solution. All rectification works are documented and certified to support your Annual Fire Safety Statement.